At NSN Unlimited, we maintain a large database of parts W23X1A1G-1, 842-201-101, 842 201 101, 830823-2, 13-0550-0010 with NSN 5925-00-866-2960 used in civil and defense applications for the aerospace, marine, and commercial manufactured by Teledyne Technologies Incorporated, Wood Electric Operations Potter And, Compunetics Inc, Tyco Electronics Corporation. Utilize our interface to browse items by part number, part type, manufacturer, and more. Obtain insights on top MRO and FBO services, Manufacturer profiles, and part catalogs.
With an unmatched supply-chain network, we are able to provide expedited shipping and same-day or next-day delivery on qualifying parts.
Ready for a quote? Submit an Instant RFQ today for NSN 5925-00-866-2960.
Alternative NSN: 5925-00-866-2960 |
Item Name: Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 008662960 |
NCB Code: USA (00) |
Manufacturers: Teledyne Technologies Incorporated , Wood Electric Operations Potter And , Compunetics Inc , Tyco Electronics Corporation |
Part No | NSN | Item Name | Manufacturer | QTY | RFQ |
---|---|---|---|---|---|
W23X1A1G-1 | 5925-00-866-2960 | circuit breaker | teledyne technologies incorporated | Avl | RFQ |
W23X1A1G-1 | 5925-00-866-2960 | circuit breaker | wood electric operations potter and | Avl | RFQ |
W23X1A1G-1 | 5925-00-866-2960 | circuit breaker | compunetics inc | Avl | RFQ |
W23X1A1G-1 | 5925-00-866-2960 | circuit breaker | tyco electronics corporation | Avl | RFQ |
842-201-101 | 5925-00-866-2960 | circuit breaker | teledyne technologies incorporated | Avl | RFQ |
842-201-101 | 5925-00-866-2960 | circuit breaker | compunetics inc | Avl | RFQ |
842-201-101 | 5925-00-866-2960 | circuit breaker | wood electric operations potter and | Avl | RFQ |
842 201 101 | 5925-00-866-2960 | circuit breaker | tyco electronics corporation | Avl | RFQ |
830823-2 | 5925-00-866-2960 | circuit breaker | wood electric operations potter and | Avl | RFQ |
830823-2 | 5925-00-866-2960 | circuit breaker | teledyne technologies incorporated | Avl | RFQ |
830823-2 | 5925-00-866-2960 | circuit breaker | compunetics inc | Avl | RFQ |
13-0550-0010 | 5925-00-866-2960 | circuit breaker | teledyne technologies incorporated | Avl | RFQ |
13-0550-0010 | 5925-00-866-2960 | circuit breaker | compunetics inc | Avl | RFQ |
13-0550-0010 | 5925-00-866-2960 | circuit breaker | wood electric operations potter and | Avl | RFQ |
111-201-101 | 5925-00-866-2960 | circuit breaker | wood electric operations potter and | Avl | RFQ |
111-201-101 | 5925-00-866-2960 | circuit breaker | teledyne technologies incorporated | Avl | RFQ |
111-201-101 | 5925-00-866-2960 | circuit breaker | compunetics inc | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABXD | BUSHING LENGTH | 0.365 INCHES MINIMUM AND 0.385 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 1.375 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.687 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.010 INCHES MINIMUM AND 1.030 INCHES MAXIMUM |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.035 INCHES MAXIMUM |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CMLP | THREAD QUANTITY PER INCH | 24 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 1.0 AMPERES AC SINGLE LOCATION AND 1.0 AMPERES DC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC SINGLE LOCATION AND 32.0 DC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 100.0 AC SINGLE LOCATION AND 150.0 DC SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.500 MINIMUM AT 200 PCT SINGLE LOCATION AND 1.800 MAXIMUM AT 200 PCT SINGLE LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | SHOCK RESISTANT AND VIBRATION RESISTANT |
TEST | TEST DATA DOCUMENT | 98571-830823 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
THSD | THREAD SERIES DESIGNATOR | UNF |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB W/SCREW |
AAQL | BODY STYLE | SINGLE POLE TYPE |
AKPX | POLE QUANTITY | 1 |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 135.0 SINGLE LOCATION |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES |
FREQ | FREQUENCY IN HERTZ | 400.0 SINGLE LOCATION |