NSN 5925-01-026-5586 (5925010265586) Datasheet

At NSN Unlimited, we maintain a large database of parts M55629 5-026, GA52621L3, 70-536DMG6, 412101-2, 256-202-101 with NSN 5925-01-026-5586 used in civil and defense applications for the aerospace, marine, and commercial manufactured by Smiths Detection Inc, Wood Electric Operations Potter And, Lucent Technologies Inc, Eaton Corporation, Raytheon Company. Utilize our interface to browse items by part number, part type, manufacturer, and more. Obtain insights on top MRO and FBO services, Manufacturer profiles, and part catalogs.

With an unmatched supply-chain network, we are able to provide expedited shipping and same-day or next-day delivery on qualifying parts.

Ready for a quote? Submit an Instant RFQ today for NSN 5925-01-026-5586

Alternative NSN: 5925-01-026-5586
Item Name: Circuit Breaker
FSG: 59 Electrical and Electronic Equipment Components
Federal Supply Class (FSC): 5925 Circuit Breakers
NIIN: 010265586
NCB Code: USA (01)
Manufacturers: Smiths Detection Inc , Wood Electric Operations Potter And , Lucent Technologies Inc , Eaton Corporation , Raytheon Company , Tyco Electronics Corporation

Cross Reference | NSN 5925010265586

Part No NSN Item Name Manufacturer QTY RFQ
M55629 5-026 5925-01-026-5586 circuit breaker smiths detection inc Avl RFQ
M55629 5-026 5925-01-026-5586 circuit breaker wood electric operations potter and Avl RFQ
GA52621L3 5925-01-026-5586 circuit breaker wood electric operations potter and Avl RFQ
GA52621L3 5925-01-026-5586 circuit breaker lucent technologies inc Avl RFQ
GA52621L3 5925-01-026-5586 circuit breaker smiths detection inc Avl RFQ
70-536DMG6 5925-01-026-5586 circuit breaker smiths detection inc Avl RFQ
70-536DMG6 5925-01-026-5586 circuit breaker eaton corporation Avl RFQ
70-536DMG6 5925-01-026-5586 circuit breaker wood electric operations potter and Avl RFQ
412101-2 5925-01-026-5586 circuit breaker wood electric operations potter and Avl RFQ
412101-2 5925-01-026-5586 circuit breaker raytheon company Avl RFQ
412101-2 5925-01-026-5586 circuit breaker smiths detection inc Avl RFQ
256-202-101 5925-01-026-5586 circuit breaker smiths detection inc Avl RFQ
256-202-101 5925-01-026-5586 circuit breaker tyco electronics corporation Avl RFQ
256 202 101 5925-01-026-5586 circuit breaker wood electric operations potter and Avl RFQ

Technical Data | NSN 5925010265586

MRCCriteriaCharacteristic
AAQLBODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE
ADAQBODY LENGTH2.479 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
ADATBODY WIDTH2.205 INCHES MINIMUM AND 2.285 INCHES MAXIMUM
ADTVCASE MATERIALPLASTIC
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJECBOSS HEIGHT0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE2.522 INCHES MINIMUM AND 2.553 INCHES MAXIMUM
AKPXPOLE QUANTITY3
AXHRMOUNTING FACILITY TYPE AND QUANTITY6 THREADED HOLE
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
BBRJSPECIAL HANDLING FEATUREMAGNETIC
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE2.0 AMPERES AC ALL LOCATIONS
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS240.0 AC ALL LOCATIONS
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1000.0 AC ALL LOCATIONS
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CPRJTRIP RELEASE METHODMAGNETIC ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT150.0 ALL LOCATIONS
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY3 TOGGLE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, AND THREE LINKED
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS
CQJXNOMINAL THREAD SIZE0.138 INCHES
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT2.100 MINIMUM AT 200 PCT ALL LOCATIONS AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT
FREQFREQUENCY IN HERTZ400.0 ALL LOCATIONS
TESTTEST DATA DOCUMENT81349-MIL-C-55629 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI
THSDTHREAD SERIES DESIGNATORUNC
TTQYTERMINAL TYPE AND QUANTITY6 THREADED STUD
ZZZKSPECIFICATION/STANDARD DATA81349-MIL-C-55629/5 GOVERNMENT SPECIFICATION

People also Searched for these Related NSN 5925010265586

Get Instant Quote

Guaranteed quotes back within 15 minutes, 24/7 x 365

Low Price Warrantied inventory at competitive prices
Find it fast Search the world's largest inventory of electronic components by manufacturer, category or part number
Get it fast All inventory ready to ship from our sellers
Quality guaranteed We sell only warrantied and traceable parts

 Semiconductor's Certifications and Memberships

Thank You for Visiting NSN Unlimited.

If You’d Like to Stay Up to Date On Our Latest, Up-To-Date NSN Parts; Kindly Explore Our Catalog and Get Quote for Your Required Part Number.

Request for Quote

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.