5950-01-088-8331 Item Description: Transformer Power | 5950 | 010888331 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
40700 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABTB | MOUNTING HOLE DIAMETER | 0.156 INCHES MINIMUM SINGLE GROUP AND 0.166 INCHES MAXIMUM SINGLE GROUP |
ACZB | FREQUENCY RATING | 30.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAR | BODY OUTSIDE DIAMETER | 1.030 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.760 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.480 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.520 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 3.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 1.30 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 2.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 2.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 20.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 6 TURRET AND 2 WIRE LEAD |