NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5920-00-103-5266 Item Description: Fuse Inclosed Link | 5920 | 001035266 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | S | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Anl250 | 2 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | III BODY STYLE | SLOTTED LIMITER |
ABDN | TERMINAL SURFACE TREATMENT | SILVER PLATED |
ABHP | OVERALL LENGTH | 3.188 INCHES NOMINAL |
ABJT | TERMINAL LENGTH | 0.875 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.438 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 0.750 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 0.875 INCHES NOMINAL |
ABTD | MOUNTING SLOT WIDTH | 0.344 INCHES NOMINAL |
AEBJ | CONTINUOUS CURRENT RATING IN AMPS | 250.000 |
AFWW | TERMINAL WIDTH | 0.750 INCHES NOMINAL |
AFWY | TERMINAL THICKNESS | 0.046 INCHES NOMINAL |
AFXE | MAXIMUM VOLTAGE RATING IN VOLTS | 32.0 AC AND 32.0 DC |
AFXF | CIRCUIT OVER-CURRENT INTERRUPTION TYPE | NORMAL INSTANTANEOUS |
AFXH | INTERRUPTION INDICATOR METHOD | VISIBLE ELEMENT |
CSQN | SHORT-CIRCUIT/INTERRUPT CURRENT RATING IN AMPS | 10000.0 |