NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-106-6067 Item Description: Switch Thermostatic | 5930 | 001066067 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
222-32nl222384 | 2 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | III OVERALL LENGTH | 4.938 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 5.125 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.875 INCHES NOMINAL |
AEVT | CAPILLARY TUBE LENGTH | 120.000 INCHES NOMINAL |
AEVU | BULB LENGTH | 2.875 INCHES NOMINAL |
AEVV | BULB DIAMETER | 0.688 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
AWTN | OPERATING TEMP RATING | 300.0 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | BRACKET |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED |
CSCF | TERMINAL TYPE | TAB W/SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 1.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 2.7 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
CTYM | CONTACT ADJUSTMENT RANGE | +150.00 TO 225.00 ACTUATION POINT DEGREES FAHRENHEIT |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT SCREW |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 DC AT SEA LEVEL SECOND VOLTAGE |
FEAT | SPECIAL FEATURES | KMOUNTING DIMENSIONS,THREE 0.281 IN. DIAMETER MOUNTING HOLES,TWO HOLES ON TOP SPACED 2.406 IN. C TO C,ONE HOLE ON BOTTOMSPACED 1.844 IN. FROM LEFT SIDE OF CASE,3.281 IN. VERTICALDISTANCE BETWEEN MOUNTING CENTERS |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE VOLTAGE |