MRC | Criteria | Characteristic |
---|---|---|
AWQT | Maximum Fueling Capacity Rating | 150.0 GALLONS PER MINUTE |
AWQW | Fueling Operating Speed At Rated Capacity In Rpm | 3450.0 |
AWQY | Maximum Defueling Capacity Rating | 100.0 GALLONS PER MINUTE |
AWQZ | Defueling Operating Speed At Rated Capacity In Rpm | 3450.0 |
AWZC | Suction Connection Characteristic | COMMON |
AWZF | Electric Motor Manufacturer Code | 07524 |
AWZG | Electric Motor Rpm | 3450.0 |
AWZK | Primer Pump | INCLUDED |
AWZL | Electric Motor Inclosure Type Per Specified Document | EXPLOSION PROOF MIL-STD-108 OR |
AWZL | Electric Motor Inclosure Type Per Specified Document | FAN COOLED MIL-STD-108 |
AWZM | Air Eliminator | INCLUDED |
AWZN | Magnetic Amplifier | INCLUDED |
AYZR | Suction Connection Size | 4.000 N STD |
AZFC | Discharge Connection Size | 2.500 N STD |
AZFD | Separate Electric Motor | INCLUDED |
ACDC | Current Type | AC |
ELEC | Voltage In Volts | 440.0 |
ARNH | Operating Position | HORIZONTAL |
ASHJ | Discharge Connection Type | FLANGED |
ASHK | Electric Motor Horsepower Rating | 12.5 |
NMBR | Quantity | 2 |
ATDA | Liquid Circulating Pump Type | RADIAL FLOW |
SR-5 | Design Control Reference Or Manufacturers Code | |
SR-5 | Design Control Reference Or Manufacturers Code | 07524 |
SR-5 | Design Control Reference Or Manufacturers Code | NC701 |
ZZZY | Reference Number Differentiating Characteristics | EXPLOSION PROOF MOTORS |
AENC | Pump Quantity | 2 |
AAYV | Discharge Connection Quantity | 2 |
FAAZ | Phase | THREE |
If You’d Like to Stay Up to Date On Our Latest, Up-To-Date NSN Parts; Kindly Explore Our Catalog and Get Quote for Your Required Part Number.
Request for Quote