MRC | Criteria | Characteristic |
---|---|---|
FEAT | SPECIAL FEATURES | MANUFACTURERS NAME: SERVOACTUATOR; ELECTIRCAL INPUT SOLENOID 28 VDC, SYNCHRO TRANSFORMER INPUT 25 VAC, 400 HZ, SERVO RATED CURRENT +/- 15 MA AT 30 V; CENTERING FORCE 25 LBS MINIMUM; LOAD LIMITER VALES SET TO LIMIT OUPUT FORCE TO 420-500 LBS; OPERATING MEDIUM MIL-H-5606 HYDRAULIC FLUID; OPERATING PRESSURE 3000 PSI PRESSURE PORT AND 1000 PSI RETURN PORT; PROOF PRESSURE 4500 PSI PRESSURE PORT AND 1500 PSI RETURN PORT; BURST PRESSURE 7500 PSI PRESSURE PORT AND 2500 PSI RETURN PORT; ACTUATOR BORE DIAMETER 0.837 TO 0.839 INCH, ACTUATOR ROD DIAMETER 0.621 TO 0.622 INCH; ACTUATOR EFFECTIVE AREA 0.248 SQ INCH |
BBBW | MOUNTING PROVISION ARRANGEMENT STYLE | THREE HOLE |
ABDR | MOUNTING PROVISION | UNTHREADED MOUNTING HOLES |
AMQZ | COMPRESSED LENGTH | 9.040 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 4.030 INCHES NOMINAL |
CKRM | INTEGRAL VALVE OPERATION METHOD | HYDRAULIC |
ATEM | EXTENDED LENGTH | 9.540 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 4.410 INCHES NOMINAL |
ABXV | BORE DIAMETER | 0.837 INCHES MINIMUM 0.839 INCHES MAXIMUM |
CKSD | DESIGN CHARACTERISTICS | DOUBLE ACTING SINGLE CYLINDER |
CLMQ | MOUNTING FACILITY DIAMETER | 0.266 INCHES MINIMUM 0.274 INCHES MAXIMUM |
CLMR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING PROVISIONS | 3.350 INCHES MINIMUM 1.000 INCHES MAXIMUM |