MRC | Criteria | Characteristic |
---|---|---|
ATEQ | SCALE TYPE | BROAD ARC DIAL |
APQB | UNIT TYPE | DIAL INDICATING |
FEAT | SPECIAL FEATURES | SWITACHABLE DUAL SCALE; READOUT PRECISION TAUT BAND DIAL METER WITH MIRROR SCALES, KNIFE EDGE POINTER, SWITCHABLE DUAL SCALES, 3 INCH SCALE LENGTH,LOW SCALE ONE HALF OF RANGE, HIGH SCALE ONE HALF OF RANGE; SCALE ALSO READS 0 TO 300 DEG C AND 200 TO 600 DEG C; SCALE DIVISION 10 DEG F OR 5 DEG C; SPECTRAL RANGE 4.8 TO 20 MICRONS; ACCURACY 1% FULL SCALE; OPERATION TEMP 35 TO 120 DEG F; REPEATABILITY 0.5%; RESPONSE TIME 1 SECOND; TARGET SIZE 1.6 INCH 0 TO 4 FT; WORKING DISTANCE 0 TO 20 FT; SIGHTING SYSTEM ENCLOSED OPTICAL; ADJUSTABLE EMISSIVITY 0.2 TO 1.0; MANUAL ZERO CALIBRATION BY HALF SQUEEZE DETENT OF THE TRIGGER SHIELD; OUTPUT TO RECORDER 0 TO 1.0 V RESPONSE TIME 0.5 SECOND; INTERNAL POWER 2 BATTERIES 5.4 V, 500 HOUR LIFE |
CSYG | SCALE MEASUREMENT RANGE | 0.000 TO 600.000 DEG FAHRENHEIT AND 500.000 TO 1100.000 DEG FAHRENHEIT |
CXCY | III PART NAME ASSIGNED BY CONTROLLING AGENCY | DIAL METER HEAT SPY THERMOMETER |
FTLD | III FUNCTIONAL DESCRIPTION | USED TO SCAN INSULATED LINES AND CHECK HEAT LEAKS, FOR PRECISE MEASUREMENT IN PLANT MAINTENANCE AND OTHER GENERAL APPLICATIONS; MOST ACCURATE WHEN PRIMARY USE IS ABOVE 600 DEG F (320 DEG C) |
STYL | STYLE DESIGNATOR | PORTABLE, HANDHELD |